How to choose a static eliminator?

Author:Hefengrelease date:2023-08-26Number of visitors:161

In practice, in the choice of dissipative appliances, the main considerations of its dissipative effect, the safety of field use and what is applicable to the electrified body, and pay attention to the economic benefits.


1, the effect of power dissipation


From the point of view of corona current, DC high-voltage power eliminator is the best effect of power elimination (power elimination, power elimination time), followed by high-frequency high-voltage power eliminator, slightly worse.


2. The safety of the eliminator includes two factors.


First, the safety of fire and explosion prevention.


 


The second is whether there is safety damage to the surrounding equipment and operators.


 


3. The condition of the charged body is also a factor that should be considered when choosing the eliminator.


For plates, films, fabrics, paper and other surface charged objects, as long as the consumption capacity to meet the requirements, you can choose DC and industrial frequency consumer; for suspended or piled up charged objects, i.e., space or volume charged objects, you should choose the ionization fan or gas source ion rods and wind mouth consumer; when the charged polarity of a certain amount of charged or charged, charged with a large amount of moving speed, you should choose the DC high-voltage consumable; installation distance should not be too large, 5cm is appropriate. Too large, 5cm is appropriate. If allowed to residual part of the electrostatic charge, should choose the gas source AC ion bar or DC high voltage ion bar; for the choice of gas source AC ion bar or DC high voltage ion bar; electric body, such as the space location allows, can choose the ion fan or high-frequency AC power eliminator. If the residual part of the electrostatic charge is allowed to remain, the gas source AC ion bar or DC high-voltage ion bar should be selected; for the selection of gas source AC ion bar or DC high-voltage ion bar; electric body, such as spatial location permits, the choice of ion fan or high-frequency AC eliminator. Another special electrostatic eliminator is known as space electrostatic eliminator, its initial purpose is to eliminate excess electrostatic charge in the space, maintain space electrostatic balance, reduce the adhesion of particles in the space, reduce particle contamination, so that the particles are filtered by the air conditioning purification system. Its working mode is DC or pulsed DC.


Installation position of electrostatic eliminator


The proper installation of the eliminator is very important. Improper installation will not only reduce the effect of electricity elimination, but sometimes it will also make the charged intensify, and even cause more harm. Therefore, how to set the position of the eliminator should be based on the site conditions, based on the measurement and analysis, the correct location of the eliminator.


Generally speaking, the eliminator should be installed at the highest potential of the charged body as far as possible. Make the elimination of electrical appliances installed in the location of the highest efficiency (such as to achieve more than 90%).


There are electrostatic sources of objects on the back of the grounding body, adjacent to the grounding body or other dissipative appliances; easy to contaminate the dissipative appliances or the temperature of 50 ℃ relative humidity in more than 70% of the environment.


The mounting angle of the eliminator should be perpendicular to the surface of the electrically charged body. In addition, the dissipator should be fixed on a solid support or fixed mechanical equipment, and require reliable grounding (such as the design of grounding components). In the actual process site or important equipment, electrostatic charged body varies greatly. According to the above principles, carrying static electricity detection table, combined with the actual situation on the site, to determine the optimal installation distance and air source flow of the dissipator, reasonable installation of the dissipator.


Static eliminator installation requirements


1 、General Provisions


On-site power supply wiring should be correct, safe and reliable, electrical equipment grounding wire should be well grounded (public grounding resistance of less than 1 ohm). The site compressed air circuit should be clean, dry, no dust, oil, water.


2, mandatory provisions


Explosion-proof static eliminator has special safety conditions, in the construction, installation and use of the process should strictly comply with the product explosion-proof certificates, product specifications and relevant national standards for electrical equipment in explosive environments.


3、 Installation should follow the principle


Static eliminator should be installed in the area of anti-static requirements. Installation of static eliminator, should follow the technical requirements for the use of products, equipment, electrical grounding is good. According to the requirements of the product specification to ensure that the electrostatic eliminator discharge electrode and the surrounding metal parts to maintain a certain safety distance. The surface of the electrostatic eliminator shall not be covered. The installation interval of the static eliminator should be determined according to the setup requirements of the anti-static area on site and the recommendations in the product manual to determine the best installation interval or consult the product supplier. The air inlet of the ionized fan static eliminator should be kept at the necessary distance from the surrounding obstacles, please refer to the product manual or consult the product supplier. There should be no obstacles between the installation location of the Static Eliminator and the object to be de-energized.


4. After the installation of the static eliminator is completed, the static eliminator should be standby or shut down, debugging, test run and start after formal use.


Hefeng Machinery Group focuses on the development and application of the surface treatment industry for more than 20 years, corona machine, corona treatment machine, plasma machine, static generator, static eliminator, dust remover, UV curing, UV power supply, electronic UV, UV light box, plasma treatment system, vacuum plasma, spark machine, plasma treatment, flame treatment machine, electronic spark machine, EDM impingement machine, surface treatment machine, macromolecule, surface flower machine, UV lamp, surface treatment machine. Surface Flowering Machine, UV lamp, UV transformer, and so on. It is a national high-tech enterprise integrating R&D, production and sales.


Our core competitiveness comes from the fact that we never stop launching new products and designing molds, and vigorously investing in the research and development of new products, it is this guiding principle that makes us different, which also enables us to become a real solution-oriented company in the industry. From the design of the solution to the final inspection of the equipment, we pay meticulous attention to every detail to ensure that the quality of our products and customer service meets the highest standards, and with our highly qualified service team and experienced technicians, we have gained an international reputation as a solid and reliable partner.


If you want to know more, you can contact online customer service!


0755-29840186

281899335@qq.com

Floor 1, Building A, Shunxing Industrial Park, No.139, Zhongxing Road, Bantian, Longgang District, Shenzhen

WeChat

All rights reserved Shenzhen HeFengJiaDa Technology Co., Ltd.File number:Guangdong ICP No. 14056343
合丰嘉大 Email
合丰嘉大 Phone
0755-29840186
合丰嘉大 WeChat
合丰嘉大
Top